OWON-VDS1022-MCP

OWON-VDS1022-MCP

Control an OWON VDS1022/VDS1022i USB oscilloscope from Claude: configure channels, capture waveforms with images, measure signals, export data, and decode serial protocols.

Category
Visit Server

README

OWON-VDS1022-MCP

Control an OWON VDS1022 / VDS1022i USB oscilloscope from Claude (or any MCP client). Configure the scope, capture waveforms, read measurements, export raw samples, decode serial protocols — and get the trace back as an image the AI can actually see, instead of reading the scope GUI and typing numbers by hand.

real capture

A real capture through this server: the scope's built-in 1 kHz probe-compensation square wave, measured at f = 1000.0 Hz, duty 49.9%.


Contents


How it works

Claude Code  ──stdio (MCP)──▶  owon-mcp server (Python)
                                    │  one shared VDS1022 handle, lock-guarded
                                    ▼
                      vendored vds1022 driver (pyusb + libusb0)
                                    │  USB bulk transfers, VID 5345 / PID 1234
                                    ▼
                            OWON VDS1022 / VDS1022i

The USB protocol is not reverse-engineered here — that work already exists. This project vendors the mature open-source driver from florentbr/OWON-VDS1022 and wraps it as 10 MCP tools. On first connect the driver automatically uploads the FPGA bitstream (bundled in vendor/vds1022/fwr/) and reads the factory calibration from the scope's flash — there is no manual firmware or calibration step.

Requirements

  • Hardware: OWON VDS1022 or VDS1022i (also sold as Multicomp MP720016/MP720017). USB identity VID 5345 / PID 1234.
  • OS: Windows (tested on Windows 11). The driver stack also works on Linux/macOS via libusb, but this repo's setup instructions are Windows-first.
  • USB driver: the libusb-win32 (libusb0) driver that OWON's official VDS_C2 software installs. If you've ever run the official software on the machine, you already have it — no Zadig / driver swap needed.
  • Python: 3.10 or newer.

Install

git clone https://github.com/Jimbwlah/OWON-VDS1022-MCP owon-scope
cd owon-scope
python -m venv .venv-win
.venv-win\Scripts\python.exe -m pip install -e ".[dev]"

# verify the install (no scope needed — runs against a mocked device)
.venv-win\Scripts\python.exe -m pytest -q     # expect: 13 passed

numpy must stay < 2. The vendored driver uses numpy-1.x integer promotion (int8 + 128); numpy 2 raises there. The pin is already in pyproject.toml — don't "upgrade" it away.

Register with Claude Code

claude mcp add owon-scope "<ABSOLUTE-PATH>\.venv-win\Scripts\owon-mcp.exe" --scope user --env "OWON_LIBUSB_DLL=C:\Program Files (x86)\OWON\VDS_C2\USBDRV\amd64\libusb0.dll"
  • Positional args (name, command) must come before --env — the --env option is greedy and will swallow the command path otherwise.
  • --scope user makes the scope available in every project; use --scope project to write a shareable .mcp.json instead.
  • OWON_LIBUSB_DLL tells pyusb where to find a libusb backend DLL. The path above is where OWON's own software ships it. Omit only if libusb0.dll is already on your PATH.

Verify: claude mcp list should show owon-scope … ✔ Connected.

Manual .mcp.json equivalent:

{
  "mcpServers": {
    "owon-scope": {
      "command": "D:\\projects\\owon-scope\\.venv-win\\Scripts\\owon-mcp.exe",
      "env": {
        "OWON_LIBUSB_DLL": "C:\\Program Files (x86)\\OWON\\VDS_C2\\USBDRV\\amd64\\libusb0.dll"
      }
    }
  }
}

The golden rule

⚠️ Close the official OWON VDS_C2 application before use. The scope allows exactly one program to hold its USB handle. If VDS_C2 (or a second MCP session) has it, connection fails with a clear error saying so. Conversely, while this server is using the scope, VDS_C2 won't see it.

Using it — example prompts

Once registered, just talk to Claude:

  • "Check the scope is connected" → scope_status
  • "Capture whatever is on the scope and show me" → scope_capture
  • "Set CH1 to 5 V range, DC coupling, x10 probe, then capture"
  • "Trigger on a rising edge through 1.5 V on CH2, 5 ms window, and show me the wave"
  • "What's the frequency and duty cycle on CH1?" → scope_measure
  • "Export the current waveform to CSV" → scope_export
  • "Decode the UART traffic on CH1 at 115200 baud" → scope_decode

The first call that touches the scope takes a few seconds (FPGA upload + calibration read); everything after is fast.

Tool reference

All voltage/time/rate arguments accept human-friendly strings: '20v', '500mv', '10ms', '50us', '100M', 'x10', 'CH1'.

scope_status()

Connects (if not already) and returns JSON: serial, hardware version, FPGA version, sampling rate, sweep mode, and per-channel config (range, probe, coupling, offset).

scope_set_channel(channel='CH1', range='20v', coupling='DC', probe='x10', offset=0.5)

Vertical setup. range is the full-scale volts across 10 divisions at the probe tip (hardware ranges 50 mV–50 V per 10 div at x1; multiply by probe factor). coupling is DC/AC/GND. offset positions zero volts on screen (0 = bottom, 1 = top). Make probe match the physical switch on your probe, or every voltage will be off by 10×.

scope_set_timebase(timerange=None, sample_rate=None)

Horizontal setup — give one or the other. timerange is the duration of the 5000-sample frame ('50us' … '2000s'); sample_rate is samples/sec ('2.5' … '100M').

scope_set_trigger(source='CH1', condition='RISE', level='0v', position=0.5, sweep='AUTO', mode='EDGE')

  • sweep='AUTO' free-runs: a capture always returns, triggered or not. Default.
  • sweep='NORMAL'/'ONCE' wait for the condition (captures time out if it never fires).
  • mode can be EDGE, PULSE, or SLOPE; for pulse/slope use conditions like RISE_SUP/FALL_INF (width comparisons).
  • position puts the trigger point left↔right in the frame (0.5 = centre).

scope_autoset()

Auto-fit range/timebase/trigger to the signal (like the front-panel Auto button).

scope_capture(timeout=8, autorange=False) — the primary tool

Captures one frame from all enabled channels and returns both a JSON measurement block (per channel) and a rendered PNG of the trace. Set autorange=True to let it fix a clipped/too-small range automatically.

scope_screenshot(timeout=8)

Same capture, image only.

scope_measure(channel='CH1', timeout=8)

Numbers only, as JSON: vpp, vmin, vmax, vavg, vrms, vamp, vbase, vtop, freq_hz, period_s, phase_deg, duty_cycle, samples, clipped. Metrics that don't apply (e.g. frequency of a DC level) come back null. clipped: true means the signal exceeded the ADC window — increase the range.

scope_export(path, format='csv', timeout=8)

Captures and writes raw samples. CSV: time_s column + one volts column per enabled channel (5000 rows). JSON: {time_s: [...], channels: {CH1: [...]}}.

scope_decode(channel='CH1', protocol='uart', baud=9600, timeout=8)

Captures and decodes a serial protocol from the trace. protocol='uart' (set baud) or 'wire' (raw logic transitions).

Typical workflows

Sanity check / first use — clip a probe onto the scope's probe-compensation tab (front metal tab, ~1 kHz square wave), then: scope_autoset → scope_capture. Expect f ≈ 1000 Hz, duty ≈ 50%. A tilted or overshooting top on the square means the probe's compensation trimmer needs adjusting — which is exactly what that signal is for.

Measure a signal — scope_set_channel (range comfortably above the expected Vpp, correct probe factor) → scope_set_timebase (aim for 2–10 periods in the window) → scope_capture. If clipped: true, increase range or use autorange=True.

Catch a one-shot event — scope_set_trigger(source, level=..., sweep='ONCE') → scope_capture(timeout=30). The capture returns when the event fires, or times out cleanly (nothing hangs).

Log data for analysis — scope_export('capture.csv'), then analyse the CSV however you like; the assistant can read it back and do the math.

Behaviour notes

  • Lazy connect: the server starts instantly; the USB connection (and the few-second FPGA upload) happens on the first tool call that needs the device.
  • Fresh-start defaults: if you capture before configuring anything, the server applies a safe free-running default (CH1, 20 V range, 10 ms window, AUTO sweep) so the first capture always works.
  • Config lives in the server process: settings persist across tool calls within a session; restarting the MCP server resets them (the scope itself keeps nothing).
  • Captures can't hang: every capture runs under a timeout; a waiting NORMAL/ONCE trigger is cleanly unblocked (dev.stop()) and reported.
  • One frame = 5000 samples regardless of timebase; sample rate = 5000 / timerange.

Troubleshooting

Symptom Cause / fix
not found or locked by another application Scope unplugged, or the VDS_C2 GUI is open — close it. Also check Device Manager shows the device under libusb-win32 devices.
No libusb backend found Set OWON_LIBUSB_DLL (see registration) or put a libusb0.dll on PATH.
Capture timed out waiting for a trigger You're in NORMAL/ONCE sweep and the condition never fired. Use sweep='AUTO', lower the level, or raise the timeout.
Voltages exactly 10× wrong The probe setting doesn't match the physical x1/x10 switch on the probe.
clipped: true, measurements look railed Signal exceeds the ADC window — increase range or call scope_capture(autorange=True).
vamp/duty_cycle suddenly null after a dependency update numpy was upgraded to 2.x — reinstall with pip install "numpy<2".
First call is slow (~5 s) Normal: FPGA bitstream upload + calibration read on first connect.

Development

src/owon_mcp/
  server.py    FastMCP server, the 10 scope_* tools
  device.py    singleton device handle, lock, lazy connect, error mapping
  measure.py   Frame → measurements dict (defensive, never raises)
  render.py    Frames → oscilloscope-style PNG (matplotlib Agg)
vendor/vds1022/  vendored driver + FPGA firmware (do not edit)
tests/test_offline.py  13 mocked-device tests — run without hardware
.venv-win\Scripts\python.exe -m pytest -q      # offline test suite
.venv-win\Scripts\python.exe -m owon_mcp.server  # run the server manually (stdio)

Verified end-to-end on real hardware (VDS1022i, fw V5.0.1, FPGA v5): FPGA upload, channel/timebase/trigger config, 1 kHz cal-wave capture (f = 1000.0 Hz, duty 49.9%), PNG render, CSV export, clip detection.

Attribution & license

The USB driver in vendor/vds1022/ (and the FPGA firmware it uploads) is the excellent open-source work of florentbr — florentbr/OWON-VDS1022 — vendored unmodified. The upstream repo carries no explicit license file; this repository is private/personal-use. If you plan to make this public or redistribute it, clarify licensing with the upstream author first. See NOTICE.md.

The MCP wrapper code (src/owon_mcp/) is © James Milward.

Recommended Servers

playwright-mcp

playwright-mcp

A Model Context Protocol server that enables LLMs to interact with web pages through structured accessibility snapshots without requiring vision models or screenshots.

Official
Featured
TypeScript
Magic Component Platform (MCP)

Magic Component Platform (MCP)

An AI-powered tool that generates modern UI components from natural language descriptions, integrating with popular IDEs to streamline UI development workflow.

Official
Featured
Local
TypeScript
Audiense Insights MCP Server

Audiense Insights MCP Server

Enables interaction with Audiense Insights accounts via the Model Context Protocol, facilitating the extraction and analysis of marketing insights and audience data including demographics, behavior, and influencer engagement.

Official
Featured
Local
TypeScript
VeyraX MCP

VeyraX MCP

Single MCP tool to connect all your favorite tools: Gmail, Calendar and 40 more.

Official
Featured
Local
graphlit-mcp-server

graphlit-mcp-server

The Model Context Protocol (MCP) Server enables integration between MCP clients and the Graphlit service. Ingest anything from Slack to Gmail to podcast feeds, in addition to web crawling, into a Graphlit project - and then retrieve relevant contents from the MCP client.

Official
Featured
TypeScript
Kagi MCP Server

Kagi MCP Server

An MCP server that integrates Kagi search capabilities with Claude AI, enabling Claude to perform real-time web searches when answering questions that require up-to-date information.

Official
Featured
Python
E2B

E2B

Using MCP to run code via e2b.

Official
Featured
Neon Database

Neon Database

MCP server for interacting with Neon Management API and databases

Official
Featured
Exa Search

Exa Search

A Model Context Protocol (MCP) server lets AI assistants like Claude use the Exa AI Search API for web searches. This setup allows AI models to get real-time web information in a safe and controlled way.

Official
Featured
Qdrant Server

Qdrant Server

This repository is an example of how to create a MCP server for Qdrant, a vector search engine.

Official
Featured